AVF7000 Series

AVF7000 Series

AVF7000 is a Vortex Flowmeter based on Von Karman theory of vortices generated by a bluff body in the pipe. The number of vortices are linearly proportional to the volumetric flow in the pipe. The AVF7000 is versatile flowmeter widely used for Gases, Steam & Liquid applications. There are no moving parts and comes with either flange or wafer connection. Standard configuration has local indication for flowrate and total flow as well as 4-20mA with HART signal and pulse output functions. The microprocessor design can filter out erroneous signals as well as interfence caused by pipe vibration.

Download

 

 

 

FEATURES

  • Simplified setup and self-diagnostic functions
  • Auto. Temperature & Pressure compensation
  • 4-20mA with HART signal and pulse outputs, user selectable
  • A very wide selection of sizes
  • Wide temperature range up to 420 oC
  • Non-volatile memory for setup and calibration

SPECIFICATION

Size: Local Display:
15,20,25,32,40,50,65,80,100,125,150 2 lines LCD
200,250,300,350,400,450,500mm 6 digit flowrate
Measuring Range: 8 digit Totalizer
Steam – 1.6 to 540,000 Kg/Hr Current Output:
Gas – 3 to 46,000 M3/Hr 4-20 mA (2 wire) with HART signal
Liquid – 0.3 to 4950 M3/Hr Load
Material: Max. 1000 
Stainless Steel 301 / 304 / 316 Pulse Output:
Accuracy           Liquid: Scale Pulse 
+/-0.7% value of reading Load
Gas & Steam 1000  – 5000 
+/-1.0% value of reading Communication:
Unit: HART(Compatible) or RS485 (MODBUS Protocol)
Nm3/h, Nm3/m, Nm3/s, m3/d, m3/h, m3/m Data Storage:
m3/s, l/h, l/m, l/s, t/d, t/h, t/m, kg/d, kg/h Operation parameter and totalizer
kg/m, kg/s, g/h, g/m, g/s figures are stored by EEPROM for more
Repeatability: than 10 years
+/-0.2% value of reading Housing Material:
Process Connection: Aluminum Alloy
Flange / Wafer Cable Entry:
Flange type Standard :M20 Option:1/2″NPTF
JIS 10K / JIS 20K / JIS 40K Power supply:
ANSI 150# / ANSI 300# / ANSI 600# 12-32 VDC
DIN PN 10 / PN 16 / PN25 / PN 40 Ni-MH Battery (3 years working Hours)
Wafer type KeyPad:
DN40~DN250 without Temp. / Pressure Sensor 3 internal keys for programming
Temperature: and display control
-40 ~ +280 oC (Standard)
Option:
-40 ~ +420 oC (Optional)
Pressure Sensor
Ambient Temperature: Pressure compensation
-20 ~ +60 oC
Signal output
Pressure: 0-30 mV DC (20 uA Power supply)
78 Kg/cm2 (Max.) Temperature Sensor
Protection Class: Temperature compensation
IP 65 Signal Output
Explosion Proof, Exd IIC T6 PT1000 (2 wires)
Intrinsically Safe, Eex ia IIC T4