AMC4000 Series

AMC4000 Series

The Aliamag AMC4000 series converter is a microprocessor based intelligent transmitter that can be paired with any of the Alia AMF series sensors. The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting.

Download

 

 

 

 

FEATURES

  • Accuracy of +/-0.3% value of reading
  • Bi-directional flow measurement, current and pulse output
  • 3 lines of LCD display flowrate and totalizer
  • Records up to 99 power on/off time
  • Battery life 2~3 years in normal working condition
  • IP67 / IP68 protection class

SPECIFICATION

Excitation: Low Flow Cutoff:
DC pulsed 0 ~ 9.9 %
Display: Self Diagnosis:
3 lines of LCD The following error message
Page 1/ Line 1  are displayed if failure occurs
5-digit flowrate – Coil failure
Page 1/ Line 2 – Power failure
11-digit forward totalizer – Overranged output
Page 1/ Line 3 – Internal error
Battery status, flow velocity – Overflow
Page 2/ Line 1 – Empty pipe
11-digit totalizer Cable Entry:
Page 2/ Line 2 Standard :PG11  Option:1/2″NPTF
11-digit reverse totalizer Protection Class:
Page 2/ Line 3 IP 67
Display instantaneous velocity IP 68 (Submersible)
Page 3
Alarm Ambient Temp.:
Flow Unit:
-25 ~ +65 oC
M3/Hr, M3/min, M3/sec, L/Hr, L/min Housing Material:
GPH, GPM, GPS, ML/H, ML/m, ML/S Aluminum alloy
Totalizer Unit: Power Supply:
M3, Gallon, Liter, ML 3.6V battery, Size D
Measuring Range: Battery Life:
Min.  0 ~ 0.15 m/s 2~3 years
Max. 0 ~ 15.0 m/s Determined by size & function
Accuracy: Communication Protocol:
+/-0.3% of reading (Velocity >=0.5 m/s) RS 485 (MODBUS protocol)
+/-0.0015 m/s (Velocity£¼0.5 m/s) Weight:
Repeatability: 2.0 Kg (Compact)
+/-0.05% of reading 4.3 Kg (Separate)
Pulse Output: Mounting:
Open collector Wall mounting
Load Bracket on 2″ pipe
3 ~ 30 Vdc, max. 20 mA Compact version ( Installed on sensor)
Pulse Rate:
1)Scaled pulse ( Liter/Pulse, other)
2)Frequency: 1~5000 Hz
Keypad:
4 control keys to change parameters
and switch display interface
Damping:
0.1~99.9s
Data Storage:
Operation parameters and totalizer are 
stored by EEPROM for more than 10 years