AUF610 Series

AUF610series

AUF610series is a portable transit-time ultrasonic flowmeter with clamp-on transducers for non-invasive liquid measurement.
Based on microprocessor and programmable flow measurement techniques the process flow can be accurately measured without interrupting the flow and with low installation costs.

Download

 

 

 

FEATURES

  • 4 line LCD to display flowrate, totalizer signal condition..etc
  • The flowmeter is designed in high accuracy +/-1.0%
  • Small sized (260 * 100 * 35mm) light-weight (600g)
  • Wide range, Velocities ( 0.01 ~ +/- 32 m/s)
  • Ni-MH Battery lasts for over 10 hours continuous operation
  • Maximum temperature 160 oC
  • Transducers for pipes size from 15 to 6000 mm (1/2″ ~ 240″)
  • Built-in magnet in transducers, no need for steady tool on metal pipe
  • Data logger which records flowrate, date, total flow, signal condition..etc
  • Response time less than 1 second

SPECIFICATION

Measuring Principle: Keypad:
Transit time difference 18 Key with tactile action
Pipe Size: Response Time:
S Type : 15 mm ~ 100 mm (1/2″ ~ 4″) Less than 1 second
M Type : 50 mm ~ 1000 mm (2″ ~ 40″) Flow Velocity:
L Type : 300 mm ~ 6000 mm (12″ ~ 240″) 0.01 ~ +/- 32 m/s
HS Type : 15 mm ~ 100 mm (1/2″ ~ 4″) Resolution:
HM Type : 50 mm ~ 1000 mm (2″ ~ 40″) 0.0001 m/s
Pipe Material: Ambient Temperature:
Cast Iron, Stainless Steel, Ductile Iron
-40 ~ +60 oC
Copper, PVC, Aluminum, Asbestos Ambient Humidity:
Fiberglass… Etc 90% RH or Less
Liner Material: Built-in Battery:
Tar Epoxy, Rubber, Mortar, Polypropylene, Ni-MH Battery
Polystyrol, Polystyrene, Polyester, Ebonite, Operation Time:
Polyethylene, Teflon… etc > 10 Hours
Display: Charger:
4 Line LCD with illumination 90 ~ 260Vac 50/60 Hz, 8-12 Hr charging
Flowrate Data Storage:
5 digit with decimal point Operation parameters and totalizer 
Totalizer figures are stored by EEPROM for more
8 digit, Forward, Reverse & Net values than 10 years
Engineer Unit Data Logger:
M3, Liter, US Gallon, Imperial Gallon, Limitless overwriting in 64 columns
Million Gallon, Cubic Feet, US Barrels, (Flowrate, totalizer, time, date included)
Imperial Barrels, Oil Barrel Output:
Time Unit Pulse (Open collector)
Second, Minute, Hour, Day Alarm:
Other High/Low with buzzer
Velocity, Date, Time, Signal condition Power Consumption:
Accuracy: Less than 2W
+/- 1% ~ +/- 2% value of reading (0.5 ~ 30 m/s) Dimensions:
+/-0.5% value of reading (Online calibration) 260 * 100 * 35 mm
Repeatability: Weight:
+/-0.2% value of reading 0.6 Kg
Protection Class:
Converter
IP65
Sensor
IP68 (Submersible)